Page 2 • DRI-STEEM XT Series Electrode Steam Humidifier Installation, Operation, and Maintenance Manual
Installation: Specifications
Table 2-1:
XT Series humidifier specifications
Model
number kW
Maximum
steam capacity
Current draw (amps)
Shipping
weight
Maximum
operating
weight
Single-phase Three-phase
lbs/hr kg/h 208V 240V 277V 480V 600V 208V 240V 480V 600V lbs kg lbs kg
XT-10 3.4 10 4.5 16.2 14.0 12.2 7.0 5.6 9.4 8.1 4.1 3.2 27.6 12.5 29.8 13.5
XT-20 6.7 20 9.1 32.2* 27.9* 24.2 14.0 11.2 18.6 16.1 8.1 6.4 29.8 13.5 38.6 17.5
XT-30 10.1 30 13.6 —————28.0 24.3 12.1 9.7 43.0 19.5 70.5 32
XT-50 16.8 50 22.7 —————46.6 40.4 20.2 16.2 43.0 19.5 70.5 32
XT-75 25.1 75 34.0 ———————30.3 24.2 65.0 29.5 114.6 52
XT-100 33.5 100 45.4 ———————40.4 32.3 67.2 30.5 116.8 53
XT-150 50.3 150 68.0 ———————
2 ×
30.3**
2 ×
24.2**
137.8 62.5 242.5 110
XT-200 67.0 200 90.7 ———————
2 ×
40.4**
2 ×
32.3**
142.2 64.5 246.9 112
Note:
* For these models, shipping weight = 43 lbs (19.5 kg) and maximum operating weight = 70.5 lbs (32 kg)
** Double units require two circuits.
XT_IOM_Jan_2008.pdf 4 11/19/2009 10:13:34 AM