DRI-STEEM XT Series Electrode Steam Humidifier Installation, Operation, and Maintenance Manual • Page 59
10. Clean the cylinder if mineral buildup is minimal.
To clean the cylinder,
flush with fresh water only. Remove the
strainer and flush. Do not use chemicals, acids, or soap to clean
the cylinder because they can cause foaming.
11. Ensure strainer is in place.
12. Insert the cleaned or new cylinder.
Ensure that cylinder is secured properly by the mounting
brackets within the unit.
13. Connect electrode plugs to cylinder electrode pins.
The electrode plug wires are color-coded. See the unit wiring
diagram for a color-coded connection diagram. This color-
coding must be followed when connecting electrode plugs to
cylinder electrode pins. On cylinders with six electrode pins,
note that there are two electrode plug wires per color. Make
sure that electrode plug wires of the same color are always
directly opposite each other when connected to the cylinder
electrode pins. Ensure that cylinder plugs fit snugly on the pins.
If cylinder plugs become loose, obtain a new replacement plug
from DRI-STEEM. See the replacement parts section of this
manual.
14. Connect the high water sensor wire.
Connect the yellow wire to the single pin surrounded by a
plastic shoulder.
15. Connect the steam hose.
16. Start up the humidifier per the instructions on Page 54.
17. If a new cylinder was installed, reset the steam cylinder
operating hours counter (LIFE) to 00.
To reset the
LIFE counter, go to the Adjustments menu using
the MODE button and choose LIFE with the SELECT button.
Enter the code number 37 with the SET button and wait until
the counter is reset to 00. Reset the steam cylinder operating
hours counter every time a new cylinder is installed. If the
counter is not reset to 00, the steam cylinder operating hours
will continue to accumulate.
Cleaning the drain valve
Always check the drain valve for need to clean before installing a
new steam cylinder. Typically, the drain valve port is as dirty as the
used steam cylinder.
1. Remove the steam cylinder as instructed on Page 58.
2. Remove the three screws and washers securing the drain cup
plate to the drain cup.
Maintenance procedures (continued)
XT_IOM_Jan_2008.pdf 61 11/19/2009 10:13:40 AM