134
4. Electro-Hydraulic Control Unit 01/2018 Rev. 1 EA(B)O-6X06
3. For replacement of most components, it is not necessary
to drain the oil from the reservoir. Seal the cover with,
for example, approximately 10 x 10 cm piece of plastic
lm, moistened with the oil itself in your central area.
Preparation Before Disassembly
1. Use a U-bracket, attached to a vise or swivel stand.
2. Secure the Electro-Hydraulic Control Unit in a U support
with two bolts and washers, interposing a soft material
between the parts to avoid damages.
4. Install a plastic film on the reservoir inlet with the
lubrication facing down and screw the cap with the
gasket to prevent air ingress and uid outlet during
operation.
0006-18
0007-18
0005-18
0004-18
CAUTION! Do not forget to remove the
plastic lm when the operation is nished,
with the risk of damaging the system if it
is not removed.
Electro-Hydraulic Control Unit
Disassembly and Assembly