4. Electro-Hydraulic Control Unit 01/2018 Rev. 1 EA(B)O-6X06
Electro-Hydraulic Control Unit
Disassembly and Assembly
0117-18
Recirculation Breather Filter
Replacement
Disassembly
1. Using a 33 mm wrench, loosen the recirculation breather
and remove it.
0119-18
2. Lubricate the gasket and Install the breather applying
the specied torque.
0118-18
Assembly
1. To mount install a new gasket (see arrow).