148
4. Electro-Hydraulic Control Unit 01/2018 Rev. 1 EA(B)O-6X06
0052-18
0053-18
0054-18
Hydraulic Pump Replacement
Disassembly
1. With the reservoir sealed (see Preparation Before
Disassembly, operations 3 and 4) and the electro-
hydraulic unit upside down, remove the two Torx T20
bolts securing the pump (yellow arrows).
5. Carefully mount the gasket on the cover and place it,
observing the three electrical contacts on the motor
connector.
6. Replace the four bolts and apply the specied torque.
CAUTION! The other two Allen bolts are
part of the pump assembly and must not
be removed.
Electro-Hydraulic Control Unit
Disassembly and Assembly

Table of Contents