6 Parameter structure
6.4 Control signal terminals
132 DC1-S…20…, DC1-S…OE1 Variable Frequency Drives 05/21 MN040058EN www.eaton.com
6.4.2.6 P-12 = 6: PI controller with AI1 totaling
Table 38: P-12 = 6: PI controller with AI1 totaling
P-15
DI1
(terminal 2)
DI2
(terminal 3)
DI3/AI2
(terminal 4)
DI4/AI1
(terminal 6)
0 START Select PI REF/f-Fix1 PI feedback No function
1 Select PI REF/AI1 REF PI feedback AI1 REF
2 Not permissible
3 START Select PI REF/f-Fix1 EXTFLT PI feedback
4 Not permissible
5 Not permissible
6 Not permissible
7
Not permissible
8 Not permissible
9 Not permissible
10 Not permissible
11 Not permissible
12 Not permissible
13 Not permissible
14 Not permissible
15 START Select f-Fix4/PI REF Select Fire Mode/Normal OP No function
16
1)
START Select f-Fix4/f-Fix2 Select Fire Mode/Normal OP No function
17
1)
START Select f-Fix2/f-Fix4 Select Fire Mode/Normal OP No function
1) If P-15 = 16 or 17, the fixed frequencies will only be enabled in fire mode.