1 Device series DC1-S…
1.4 Rated operational data
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives 05/21 MN040058EN www.eaton.com 13
Nameplate inscription
The inscription of the nameplate has the following meaning (example):
Inscription Meaning
DC1-S27D0FN-A20CE1 Part no.:
DC1 = DC1 series variable frequency drive
S = Single-phase mains connection/single-phase motor connection
2 = 230 V mains voltage category
7D0 = 7 A Rated operational current (7-decimal-0, output current)
F = Integrated radio interference suppression filter
N = No braking chopper
A = LED display (7-segment text display)
20 = IP20 degree of protection
C = Coated boards
E1 = Expansion, version 1
Input
Rated operational data of mains connection
Single-phase AC voltage (U
e
1~ AC)
Voltage: 110 - 150 V, Frequency: 50/60 Hz, Input phase current: (9.3 A)
Output
Load side (motor) rated operational data:
Single-phase AC voltage: (0 - U
e
), Output phase current: (7 A),
Output frequency: (0 - 500 Hz)
Assigned motor output:
0.75 kW with 230 V/1 HP with 230 V for an internally cooled or surface-cooled
single-phase AC motor (50 Hz/60 Hz)
Serial No.:
Serial number
IP20 Degree of protection of the housing: IP 20, UL (cUL) Open Type
Software Software version (2.0)
05102016 Manufacturing date: 10/05/2016
Max amb. 50 °C Maximum permissible ambient air temperature (50 °C)
Variable frequency drive is an electrical apparatus.
Read the manual (in this case MN040058EN) before making any electrical
connections and commissioning.