22
Active Track (beta version)
© 2013 EBS
In case of SMS message, the message consists of parameter names and its
values. Each SMS message begins user defined access code, which in a particular
case may be empty. When sending more than one parameter, they need to be
separated by space character.
You may configure following parameters:
SERVER=server’s_address
Specifies IP number or domain name of the computer Server Software is
installed at. Server must be connected to the Internet with static and public IP
number.
PORT=server’s_port
Enters port of server which monitors incoming data on the server.
APN=apn
Access point to network. APN is available at your GSM Provider.
UN=apn_user_name
APN user name. UN is available at your GSM Provider.
PW=apn_user_password
APN user password. PW is available at your GSM Provider.
Attention: These parameters are needed to establish connection with
communication server. If receiving device is OSM.2007 (Monitoring System Receiver
made by EBS), then configuration steps of Active Track device consists in:
- send SMS message with described on the previous page parameters (SERVER,
PORT, APN, UN and PW),
- wait until device connects to the server,
- remaining parameters send over GPRS link, using Console function of OSM.2007
TPERIOD=time_in_minutes
Defines time between following tests, which are sending to server through
GPRS link. If no parameter is programmed, device will use default value - 1
minute.
If value ends with letter „s” time will be recognized in seconds. Minimal interval
between tests is 10 seconds.
DNS1=dns1
Specifies primary DNS server address and should be defined only if is obligatory.
DNS2=dns2
Specifies secondary DNS server address and should be defined only if is
obligatory.