41
Configuration
© 2013 EBS
9.2.3.3.1.1 ManDown
The ManDown functionality allows for monitoring and signalling motion of the guard
holding the device. The lack of motion may result from an assault, but also from
neglecting duties.
The adjustable parameters are:
Sensitivity - specifying vibration threshold below which the device determines
its state as lack of motion
Time of immobility before the alarm - the time following which the device
generates ManDown alarm in case of immobility
Pre-alarm - functionality allowing the user to get information on detection of
immobility before the ManDown alarm is generated
Time of immobility before the pre-alarm generation - time after which the
device in a static state signals immobility to the user
Note:
The method of pre-alarming the device’s user of the ManDown function
activation (in other words: of the approaching generation of ManDown alarm) is
described in point Microphone & Speaker .