Configuration
© 2013 EBS
g) prealarm signalling (eg. ManDown)
Note:
It is not necessary to give all the parameters, only the first X, for example:
VOLUME=2 sets the signal only for start RFID loop, the other parameters
remain unchanged. As a consequence, to set the parameter to the position of
N all preceding parameters should also be set. For example, you can not set
signaling for "c) Discharged battery warning" without giving "a) Start RFID
loop" warning and "b) Read RFID confirmation" in correct order.
RFID=t,n
(this parameter is only for device version with built in RFID transponders
reader)
Enables several RFID tags read-out after one push of Read-out button.
Parameters of this option:
t - sets maximum time between different RFID tags read-outs,
n - maximum number of RFID tags that can be read after single push of
Read-out button (if n=0 then there is no limit)
TCPWDT=t
sets TCP link control, defines times between lost of TCP connection and reset
of GSM modem
t time period [in minutes, range: 5 - 999]
To disable this function t must be an empty string.
GSMWDT=t
Sets GSM link control, defines time between lost of GSM connection and reset
of GSM modem.
t time period [in minutes, range: 5 - 999]
To disable this function t must be an empty string.
GETCFG
Gets primary communication parameters of device in form: SERVER PORT APN
UN PW SMS TPERIOD
KILL
Sending this command remotely resets the device.
Example of SMS configuration text message (access code is 1111, skip quotes):
"1111 APN=PGuard.gprs UN=PGuard PW=PGuard_pass SERVER=gprs.com
PORT=6670 DIAL=1,600112233,0 DIAL=2,500445566,3 DIAL=3,600778899,3
SMS=500445566 DT=05/12/15,13:04 TPERIOD=5"
Example of SMS configuration text message (access code is empty, the first is a space