24 ecom-ST 1.0
The CO sensor can be switched off with <F3> in order to protect it from
excessively high concentrations. The automatic switch-off takes place at
2500 ppm or 4000 ppm (depending on the model).
With <F4> it is also possible to switch from the measured value display to a
menu item or a function selected previously (see chapter Adjustments).
Possible settings are: Fuel type, Eff. (C), Internal, Adjustments, Standby,
Display values, Purge.
Adjustment of the measurement screens
To change the position of the measured and calculated values in the
measurement screens 1 to 3, proceed as follows:
1. Activate the function with <Enter> / "Display values" / <Enter>.
2. Select the desired line with the cursor keys (up / down).
3. Select the desired parameter with the cursor keys (right / left).
4. Repeat the procedure until the change is completed.
5. Deactivate the function with <Enter>.
The measured and calculated values in measurement screen 4 can be set
with the cursor keys (right / left).
The position of the measured and calculated values (flue gas
analysis) can be changed at user´s choice.
NOTE