ecom-ST 1.0 25
4.4 Draught measurement
For an exact measurement, it is advisable to
recalibrate the sensor as the differential
pressure sensor tends to drift due to its
sensitivity. Disconnect the draught hose on the
device and press <F4>. The sensor is
recalibrated. Reattach the draught hose. The
display shows the exact measured value, that
can be frozen with the <Store> key.
Pressure
Draught -0.12 hPa
Recorded value:
-0.12 hPa