Switch Cluster Commands
4-315
4
Command Mode
Privileged Exec
Command Usage
This command only operates through a Telnet connection to the Commander
switch. Managing cluster Members using the local console CLI on the
Commander is not supported.
There is no need to enter the username and password for access to the
Member switch CLI
.
Example
show cluster
This command shows the switch clustering configuration.
Command Mode
Privileged Exec
Example
show cluster members
This command shows the current switch cluster members.
Command Mode
Privileged Exec
Example
Vty-0#rcommand id 1
CLI session with the 24/48 L2/L4 GE Switch is opened.
To end the CLI session, enter [Exit].
Vty-0#
Console#show cluster
Role: commander
Interval heartbeat: 30
Heartbeat loss count: 3
Number of Members: 1
Number of Candidates: 2
Console#
Console#show cluster members
Cluster Members:
ID: 1
Role: Active member
IP Address: 10.254.254.2
MAC Address: 00-12-cf-23-49-c0
Description: 24/48 L2/L4 IPV4/IPV6 GE Switch
Console#