9.4.13 ReadMeasValue
Function:
Reads the motor temperature, motor current, measured rotational speed, and
control unit temperature.
The motor temperature value is the same temperature as "ReadMotorTemp".
The measured rotational speed value is the same as "ReadMeas" parameter 2
(Measured rotational speed).
Transmission Frame:
PCSIM
Stx
0
0
1
? [ Etx
LRC
SIMPC
Ack
PCSIM
Ack
SIMPC
Stx
0
0
1
Sp
[ Parameter 1 to 8
Etx
LRC
*1:
The HEX code of ASCII character ' [ ' is "5B".
Parameter
Item Data format Remarks
1 [System reservation]
136-bits hexadecimal
coded ASCII
2
Motor temperature
(Unit: °C)
16-bits hexadecimal
coded ASCII
3 [System reservation]
8-bits hexadecimal
coded ASCII
4
Motor current
(Unit: 0.1 A)
8-bits hexadecimal
coded ASCII
5 [System reservation]
24-bits hexadecimal
coded ASCII
6
Measured rotational speed
(Unit: Hz)
16-bits hexadecimal
coded ASCII
7 [System reservation]
48-bits hexadecimal
coded ASCII
8
Control unit temperature
(Unit: °C)
16-bits hexadecimal
coded ASCII
*1
*1