STP-iX455/iXL455 Series Instruction Manual
9-1
Operation
9 Serial Communication Protocol
9.1 Serial Communication
The STP-iX455/iXL455 series is provided with compliant serial RS232/RS485 interface.
Prepare the user application according to this protocol procedure. Operation
instructions and information, such as the running state and setting values of the STP
pump can be set by the software.
The STP pump equips the serial ports for connecting the user application, STP-link
(optional accessory), or the display unit iDT-001 (optional accessory) (see Figure 9.1).
A serial port located the STP pump is called a serial interface module (hereafter
referred to as SIM). The equipment, which can communicate with the STP pump via
RS232/RS485, is called a PC.
Figure 9.1 Serial Port
STP Pump
PC
(User application)
COM1
(X3 COM1 connector)
COM4
(X4 OPTION PORT
connector)
Power supply unit
(optional accessory)
STP-Link or
Display unit
(optional accessory)
COM3
STP-Link or
Display unit
(optional accessory)
COM2
(X5 STP-Link connector)
4
1 2
3
5
6 7
FAILURE
ROTATION
POWER
X5 STP-Link
X6 VENT VALVE
X2 REMOTE
X1 DC POW ER
X4 X3 COM1