STP-iX455/iXL455 Series Instruction Manual
4-14
Installation
2) When securing the inlet port flange with claw clamps
Refer to Table 4.3 for destructive torque.
When securing the inlet port flange with only the claw clamp, the vacuum equipment
cannot withstand the maximum destructive torque generated by the worst-case failure.
To make the vacuum equipment withstand abnormal torque, secure the base with all 4
screw-holes for legs or all 4 legs. Follow "CAUTION" in Section 4.3.4 about legs and bolts
for securing the base.
For the claw clamp-type, use the required number of claw clamps as specified in Table 4.4.
Position the claw clamps evenly on the circumference.
Table 4.4 Number of Claw Clamps by Size of Flange
Size
of Flange
Number of Claw Clamps
ISO160
or less
4
or more
ISO200
to
250
6
or more
ISO320
or more
8
or more
Figure 4.8 Example of Securing the STP Pump