Installaon
Installaon safety
WARNING:
Risk of injur
y or damage to equipment. Follow the safety instrucons and take note of all
appropriate precauons.
• When r
eferring to a manual supplied as a Supplementary Publicaon, all of the
WARNING and CAUTION instrucons in the manual must be obeyed.
• A suitably trained and supervised technician must install the T-Staon 85.
• Check that all the required parts are available and of the correct type before
commencing work.
• Ensure that the installaon technician is familiar with the safety procedures which
relate to the products pumped.
• Wear the appropriate safety clothing when coming into contact with contaminated
components.
• Isolate the other components in the system from the electrical supply so that they
cannot be operated accidentally.
• Do not reuse O-rings and co-seals if they are damaged.
• Dispose of components, grease and oil safely (refer to Disposal on page 32).
• Take care to protect sealing faces from damage.
• Leak tesng the system aer installaon is complete to ensure opmum vacuum
performance is recommended.
Unpack and inspect
1. Remove the outer cover and all packing materials, remove the protecve covers from
the inlet and outlet ports, inspect the system for any damage.
2. If the T-Staon 85 is damaged, nofy the supplier and the carrier in wring within
three days; state the item number of the T-Staon 85 together with the order number
and the supplier's invoice number. Retain all packing materials for inspecon. Do not
use the pump if it is damaged.
3. Check that the package contains the items listed in Table 1 on page 11. If any of
these items are missing, nofy the supplier in wring within three days.
4. If the pump is not to be used immediately, replace the protecve covers and store in
suitable condions as described in Storage on page 31.
Table 1
Checklist of items
Quanty Descripon Check
1 T-Staon 85
❏
1 CD instrucon manual P450-00-000
❏
1 Ultragrade 15 oil 1 litre (supplied with E2M1.5 only)
❏
1 Inlet seal (either trapped O-ring, co-seal or copper
c
ompression gasket suitable for the inlet ange type)
❏
D395-94-880A - Installaon
Page 11