Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
DOC. NO. 5956.573.05 P. 1 6 / 8 8
(*) For the other equipment families, see par. B PROGRAMMING SHEETS.
** The table given below indicates the delay between transit of the rack on the autorinse lever and stopping of
the rinse phase.
E.g. in a WTM165 working at high speed (165 racks/h) the rinse pump keeps operating for 11 seconds after
the last rack has released the autorinse lever.
Modular
parameter
Compact
parameter
Family
Nr.
Para
meter
Nr.
Parameter description Unit of
measure
Min Max Factory
setting
[for
WTM165
(*)]
Buzzer
enabled.
1 29 Enables machine buzzer.
Modular Rack Type:
- 0/“No” machine buzzer disable
- 1/“Yes” machine buzzer enable.
-No
(0)
Ye s
(1)
Ye s
(1)
Compact Rack Type:
- “0” machine buzzer disable
- “1” machine buzzer enable.
-01 0
Demo
mode
1 30 Demo mode.
Modular Rack Type:
- 0/“No demo” normal operation.
- 1/“Demo mec” the users are not activated and the
inputs are not read, but communication between the
USER card and POWER cards is maintained .
- 2/“Demo user” the users are not activated, the
inputs
are not read, the USER card doesn’t communicate
with the POWER cards.
- - - No demo
(0)
Compact Rack Type:
- “0” normal dishwasher operation.
- “1” the users are not activated and the inputs are not
read, but communication between the USER card
and POWER cards is maintained .
- “2” not available on these models.
--- 0
Rinse
autostart.
1 31 Indicates the type of command for the start of the
rinse phase. It can be set to “Mechanical” (1) only if
the special mechanical lever is present in the rinse
zone.
**
Sof
twa
re/0
Mec
hani
cal/
1
Software/0
Max.
motor
curr.
***
***
1 32 Indicates the max. current deliverable to the gear
motor by the inverter if the automatic gear motor
current setting procedure was not carried out.
If the supplied current is higher than this value,the
message “CROCKERY STUCK” appears on modular
Rack Type no USA and the message “
” on compact Rack Type.
dec
Amp.
0
-
40
-
35
(110Vac
gearmotor)
0
(230Vac
gearmotor)
Set
default
par.
1 33 It allows all the parameters to be set to their default
value. The set parameters are those of a WTM165
without DT.
The parameter set to “Yes” (1) automatically returns
to “No” (0).
-No/
0
Yes/
1
No/
0