11. SYNTH TRACK PARAMETERS
41
11.4.1 ATK A
Attack Time sets the length of the attack phase of the modulation envelope for operator A. (0–127)
11.4.2 DEC A
Decay Time sets the length of the decay phase of the modulation envelope for operator A. (0–127)
11.4.3 END A
End Level sets the end level of the modulation envelope for operator A. (0–127)
11.4.4 LEV A
Level sets the modulation amount from operator A. (0–127)
11.4.5 ATK B
Attack Time sets the length of the attack phase of the modulation envelope for operator group B (B1 and
B2). (0–127)
11.4.6 DEC B
Decay Time sets the length of the decay phase of the modulation envelope for operator group B (B1 and
B2). (0–127)
11.4.7 END B
End Level sets the end level of the modulation envelope for operator group B (B1 and B2). (0–127)
11.4.8 LEV B
Level sets the modulation amount from operator group B (B1 and B2). (0–127)
The LEVEL parameter for B is macro mapped to both operator B1 and B2 and control their modulation
amount as per this graph:
B1
B2
Level
Parameter value 6443 85
0
127
If you wish to use frequency modulation, it is important that you turn the LEV parameters up,
since they set the amount of frequency modulation in the FM engine.
11.5 SYN2 PAGE 2
The parameters on the SYN2 pages control various aspects of the FM synthesis, mainly the amount of
frequency modulation together with the operator envelopes and their behavior.
Press [SYN2] twice to access this parameter page.