Platform Safety EEC-0061 V1.1
Platform Safety
H. The personnel platform and crane are not
insulated. Do not operate near power lines
or electrical hazards. Recommended
minimum working distances are to be
maintained when working near power lines
or electrical hazards. Distances are based
on voltages of electrical hazards.
I. If electrical voltage is unknown, assume
maximum voltage and maintain the
maximum clearance of at least 45 feet.
You must use a signalperson on the
ground to guide the operator.
J. Rated loads account for wind to 20 MPH (32 km/hr) and 15 MPH (24 km/hr) on jib
capacities. Above these wind velocities, loads and/or boom lengths must be
appropriately reduced for safe operation. Cease all personnel lifting activities if
hazardous conditions such as electrical storms, snow, ice, sleet or any other
adverse conditions occur.
K. Modification of the structural integrity of the personnel platform shall not be done
without written approval of the manufacturer.
L. Personnel platforms are to be used only for personnel, their tools, and sufficient
materials for the workers to accomplish their job. Platforms shall not be used to
transport bulk materials.
M. Properly stow the personnel platform, jib, boom, and outriggers prior to road travel.
Special Work Considerations
Special precautions are to be taken for some, but not all, special work situations.
A. When welding from the personnel platform electrode holders shall be protected from
contact with the metal components of the personnel platform.
B. When personnel lifts occur over water, personal flotation devices shall be provided
and required to be worn. Platform personnel shall wear a body (fall protection
MINIMUM CLEARANCE REQUIREMENTS
Minimum
Nominal Voltage kV Distance
(Phase to Phase) Required
Up to 50 10 feet
Over 50 to 200 15 feet
Over 200 to 350 20 feet
Over 350 to 500 25 feet
Over 500 to 750 35 feet
Over 750 to 1000 45 feet

Table of Contents