16 BA-en-3041-2008_PC
Information on performance level applications:
The 24 V DC power supply to be used must be tested according to the
EN 60950-1 or EN 62368-1 standard / must meet the applicable PELV
(protective extra low voltage) or SELV (safety extra low voltage)
requirements (see Chapter 3.8.1 "Connecting the supply voltage 24 V
DC”, page 24, Chapter 8 "Technical Specifications POWER CHARGER
PC_ _”, page 77).
A redundant release signal is required if the generator must comply
with the safety requirements of DIN EN 13849. To this end, the two
signals “Release +” and “Release -” must be transmitted via separate
switching paths; hardwiring of the two release signals +/- is prohibited
(see Chapter 3.10.1 "Analog interface Charging”, page 28, Chapter
3.10.2 "Analog interface Discharging”, page 30).
Release analog interface
Be sure to connect the signals properly to avoid damaging the genera-
tor. Always use shielded cables as interface cables; the shield must be
contacted at both ends (see Chapter 3.10.1 "
Analog interface Charg-
ing”, page 28, Chapter 3.10.2 "Analog interface Discharging”, page 30).
The enable signals for charging / discharging must be switched off at
least once a year for 400 ms or longer so that errors in the enabling
logic may be detected.
The charging / discharging bars must be cleaned at least once a week
to ensure that they function properly (see Chapter 4.3 "Releasing the
high voltage”, page 41).
The voltage at the input plugs of the 24 V DC supply voltage, the ana-
log interfaces for charging and discharging and the field bus interfaces
must not exceed 60 V DC (see Chapter 3.8.1 "Connecting the supply
voltage 24 V DC”, page 24, Chapter 8 "Technical Specifications
POWER CHARGER PC_ _”, page 77).