EasyManua.ls Logo

ELTEX POWER CHARGER PC - Warning Message Guidance

ELTEX POWER CHARGER PC
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72 BA-en-3041-2008_PC
6.2 Warning messages
If a warning message appears, the output of the high voltage will not be
disrupted.
Note!
Warning messages are not saved. The disruption of the supply voltage
automatically cancels the malfunction message.
The table below shows a list of the warning numbers.
104 Nein Diagnostic error:
hardware release
channel 2
discharging
Interrupt the supply voltage.
Check the release switching..
If this error occurs again, send in the device
for repairs.
105 Nein Diagnostic error:
software release
discharging
Interrupt the supply voltage.
Check the release switching..
If this error occurs again, send in the device
for repairs.
106 Nein Diagnostic error:
release
discharging
inconsistent
Interrupt the supply voltage.
Check the release switching..
If this error occurs again, send in the device
for repairs.
Error
number
Error
clearable
Cause Measure
Warning
number
Cause Measure
1 Error cannot be cleared.
Interrupt the supply voltage.
If this error occurs again, send in the device
for repairs.
2 Clearable error has not
occurred.
Clear the warning.
3 Invalid error counter
Clear the warning.
4 The release of the output
stage has been disabled.
An error occurred during the release of the
high voltage.
Do not send the release telegram again.
First eliminate the cause of the error, then
clear the warning.

Table of Contents