BA-en-3041-2008_PC 73
7Battery
voltage too low
• Change the integrated battery; see discription
Chap. 11.
• Change must be carried out by qualified per-
sonnel.
8 Flash count of hard flashes,
limit exceeded
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
9 Flash count of soft flashes,
limit exceeded
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
13 Pollution of the bar charging
• Clean the bar.
16 Current limit
charging
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
17 Voltage limit
charging
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
22 Voltage limit
discharging
• Clean the bar.
• Check the mounting position.
23 Current imit
discharging
• Clean the bar.
• Check the mounting position.
24 Power limit
charging
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
26 Temperature
• Check the installation of the generator.
• Improve the cooling of the
housing.
• Reduce the ambient temperature.
• Reduce the setpoint value.
29 Power limit
discharging
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
• Reduce the power input.
• Reduce the discharge frequency.
Warning
number
Cause Measure