3.9.2 ModbusTCP (optional)
The generators of the POWER CHARGER family can be integrated into
an existing LAN network using the TCP/IP standard ModbusTCP protocol.
All variants with this option support the following functions:
10/100 Mbit/s transmission
DHCP protocol for setting the IP address (active by default)
Static IP address is possible
Cyclic retrieval of process data
Setting and reading of the parameter set
LED output of the network and connection status
A complete description of supported commands and assignment of pro-
cess data, parameters etc. in the respective registers is available in the
Downloads area at www.eltex.com/support/download service.
Caution!
The generator must be connected to the network by means of suitable,
shielded cables; the shield must be contacted at an appropriate place on
both ends. We recommend using cables of category Cat 5e or higher.
Fig. 15:
Connetor pin
assignment
Plug connector
M12x1 D-coded
1 Tx +
2 Rx +
3 Tx -
4 Rx -
2 x Socket female
F00055y

Table of Contents