18 BA-en-3041-2008_PC
Mounting position
Chapter 5 "Installation of the high voltage generator, vertical” and Chapter
6 "Installation of the high voltage generator, horizontal” show the two per-
mitted mounting positions. Please note that the specified ambient tempe-
rature must not be exceeded at any time on any side of the housing.
3.2 Ground connection
Attention!
A functioning ground connection must be ensured during the entire ser-
vice life of the generator. The ground cable should have a minimum cross
section of 1.5 mm
2
and and should be routed with the shortest possible
distance to the machine frame. A cross section of 2.5 mm
2
is required for
cable lengths exceeding 0.5 meters. Eltex recommends using the ground
cable supplied with the generator.
Ground terminal
Insert the ground cable into the side slot of the open terminal until it pro-
jects from the opposite side. Then tighten the integrated safety screw of
the terminal up to the stop (5 Nm).
Fig. 6:
Installation of the
high voltage
generator,
horizontal
Z-116036dy_1