BA-en-3041-2008_PC 71
91 No Diagnostic error:
hardware release
channel 2
charging
Interrupt the supply voltage.
Check the release switching.
If this error occurs again, send in the device
for repairs.
92 No Diagnostic error:
software release
charging
Interrupt the supply voltage.
Check the release switching.
If this error occurs again, send in the device
for repairs.
93 No Diagnostic error:
release charging
inconsistent
Interrupt the supply voltage.
Check the connection of the bar.
If this error occurs again, send in the device
for repairs.
96 No Diagnostic error:
monitoring
discharging
channel 1
Interrupt the supply voltage.
Check the connection of the bar.
If this error occurs again, send in the device
for repairs.
97 No Diagnostic error:
monitoring
discharging
channel 2
Interrupt the supply voltage.
Check the connection of the bar.
If this error occurs again, send in the device
for repairs.
98 No Diagnostic error:
monitoring
high voltage
discharging
Interrupt the supply voltage.
If this error occurs again, send in the device
for repairs.
99 No Diagnostic error:
overvoltage
channel 1
discharging
Interrupt the supply voltage.
Clean the bar.
If this error occurs again, send in the device
for repairs.
100 No Diagnostic error:
overvoltage
channel 2
discharging
Interrupt the supply voltage.
Clean the bar.
If this error occurs again, send in the device
for repairs.
103 No Diagnostic error:
hardware release
channel 1
discharging
Interrupt the supply voltage.
Check the release switching..
If this error occurs again, send in the device
for repairs.