BA-en-3041-2008_PC 71
91 No Diagnostic error:
hardware release
channel 2
charging
• Interrupt the supply voltage.
• Check the release switching.
• If this error occurs again, send in the device
for repairs.
92 No Diagnostic error:
software release
charging
• Interrupt the supply voltage.
• Check the release switching.
• If this error occurs again, send in the device
for repairs.
93 No Diagnostic error:
release charging
inconsistent
• Interrupt the supply voltage.
• Check the connection of the bar.
• If this error occurs again, send in the device
for repairs.
96 No Diagnostic error:
monitoring
discharging
channel 1
• Interrupt the supply voltage.
• Check the connection of the bar.
• If this error occurs again, send in the device
for repairs.
97 No Diagnostic error:
monitoring
discharging
channel 2
• Interrupt the supply voltage.
• Check the connection of the bar.
• If this error occurs again, send in the device
for repairs.
98 No Diagnostic error:
monitoring
high voltage
discharging
• Interrupt the supply voltage.
• If this error occurs again, send in the device
for repairs.
99 No Diagnostic error:
overvoltage
channel 1
discharging
• Interrupt the supply voltage.
• Clean the bar.
• If this error occurs again, send in the device
for repairs.
100 No Diagnostic error:
overvoltage
channel 2
discharging
• Interrupt the supply voltage.
• Clean the bar.
• If this error occurs again, send in the device
for repairs.
103 No Diagnostic error:
hardware release
channel 1
discharging
• Interrupt the supply voltage.
• Check the release switching..
• If this error occurs again, send in the device
for repairs.
Error
number
Error
clearable
Cause Measure