SMG digital gateway 165
src verify
<ON_OFF>
on/off
Control media traffic reception from
the IP address and UDP port specified
in the SDP communication session
description (on); otherwise, accept
traffic from any IP address and UDP
port (off)
STUN ip
<IPADDR>
IP address in the
AAA.BBB.CCC.DDD
format
Set an address of the STUN server
the requests will be sent to
STUN port
<PORT>
1-65535
Set a port of the STUN server the
requests will be sent to
STUN use
<YES_NO>
no/yes
Use the STUN server to determine
the public IP
t38 bitrate
<BITRATE>
nolimit/2400/4800
/
7200/9600/12000/
14400
Set the maximum transfer rate of a
fax transmitted via the Т.38 protocol
t38 disable
Disable fax reception via the Т.38
protocol
t38 enable
Enable fax reception via the Т.38
protocol
t38 fillbitremoval
<T38_FBR>
on/off
Enable/disable padding bit removals
and inserts for the data which is not
related to ЕСМ
t38 pte
<T38_PTE>
10/20/30/40
Set the frequency of Т.38 packet
generation, in milliseconds
t38 ratemgmt
<T38_RATE_MGMT>
localTCF/
transferredTCF
Set a rate management method:
local TCFthe method requires the
TCF tuning signal to be locally
generated by the recipient gateway;
transferred TCFthe method
requires the TCF tuning signal to be
sent from the sender device to the
recipient one;
t38 redundancy
<T38_REDUNDANCY>
off/1/2/3
Enable redundant frames for error
control, offdisable
timer enable
<YES_NO>
no/yes
Enable/disable RFC4028 SIP session
timers
timer refresher
<REFRESHER>
uac/uas
Set the party that performs session
renewal
timer session Min-SE
<MIN_SE>
90-32000
Set the minimum session state
control period, in seconds. This value
should not exceed the timer session
expires forced termination timeout
timer session expires
<EXPIRES>
90-64800
Set a period of time in seconds
before a forced session termination if
the session is not renewed in time
trunk
<TRUNK>
0-31
Set a trunk group number for an
interface
trusted network
<YES_NO>
yes/no
Enable the trusted network option
username
<USERNAME>
String, 15
characters max.
Specify a username for
authentication
VAD_CNG
< ON_OFF >
on/off
Enable/disable voice activity
detector / comfort noise generator
for an interface
vbd codec
<CODEC>
G.711-U, G.711-A
The codec which is used for VBD data
transmission