G3SeriesPROFIBUS‐DPTechnicalManual
Page 36
TDG3PTTM1-2EN 02/09
Subject to change without notice
www.numatics.com/g3
Digital Input Modules
Input Mapping
BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X Input 7 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Input 0
Diagnostic Telegram
BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X
Conn. H
SCP Status
Conn. G
SCP Status
Conn. F
SCP Status
Conn. E
SCP Status
Conn. D
SCP Status
Conn. C
SCP Status
Conn. B
SCP Status
Conn. A
SCP Status
One Digital Input per Connector - M12 Female Modules
Module Part No. I/O Type
Short Circuit Protection
(SCP)
Input Points
240-210 NPN (Sinking)
240-206 PNP (Sourcing)
YES – Visual 8