G3SeriesPROFIBUSDPTechnicalManual
Page 37
TDG3PTTM1-2EN 02/09
Subject to change without notice
www.numatics.com/g3
Two Digital Inputs per Connector - M12 Female Modules
Module Part No. I/O Type
Short Circuit Protection
(SCP)
Input Points
240-209 NPN (Sinking)
240-205 PNP (Sourcing)
YES – Visual 16
Input Mapping
BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X Input 7 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Input 0
X+1 Input 15 Input 14 Input 13 Input 12 Input 11 Input 10 Input 9 Input 8
Diagnostic Telegram
BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X
Conn. H
SCP Status
Conn. G
SCP Status
Conn. F
SCP Status
Conn. E
SCP Status
Conn. D
SCP Status
Conn. C
SCP Status
Conn. B
SCP Status
Conn. A
SCP Status