G3SeriesPROFIBUSDPTechnicalManual
Page 56
TDG3PTTM1-2EN 02/09
Subject to change without notice
www.numatics.com/g3
Example No. 1 Table
Output Table
BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
Valve Coil
No. 7
Valve Coil
No. 6
Valve Coil
No. 5
Valve Coil
No. 4
Valve Coil
No. 3
Valve Coil
No. 2
Valve Coil
No. 1
Valve Coil
No. 0
1
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Valve Coil
No. 11
Valve Coil
No. 10
Valve Coil
No. 9
Valve Coil
No. 8
2
(Optional)
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
3
(Optional)
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Input Table
BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
Discrete Input
No. 7
Discrete Input
No. 6
Discrete Input
No. 5
Discrete Input
No. 4
Discrete Input
No. 3
Discrete Input
No. 2
Discrete Input
No. 1
Discrete Input
No. 0
1
Discrete Input
No. 15
Discrete Input
No. 14
Discrete Input
No. 13
Discrete Input
No. 12
Discrete Input
No. 11
Discrete Input
No. 10
Discrete Input
No. 9
Discrete Input
No. 8
2
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog Input
No. 1 (LSB)
3
Analog Input
No. 1 (MSB)
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
Analog
Input No. 1
4
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog Input
No. 2 (LSB)
5
Analog Input
No. 2 (MSB)
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
Analog
Input No. 2
6
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog Input
No. 3 (LSB)
7
Analog Input
No. 3 (MSB)
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
Analog
Input No. 3
8
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog Input
No. 4 (LSB)
9
Analog Input
No.4 (MSB)
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
Analog
Input No. 4
The number of Outputs Bytes Allocated for valve coils may be optimized and
set to 8, 16, 24 or 32 coils.