Reference Manual
00809-0100-4840, Rev. BA
July 2008
C-3
Rosemount 3100 Series
MENUS ON THE 3102
AND THE 3105
Figure C-2. Main Menu Programming on The 3102/3105
PV Display
(Diagnostics )
(Duty)
Diagnostics
(Loop test )
(Distance)
(PV)
Loop test
(Eng setup )
(PV )
Eng setup
(PV)
(2s)
(2s)
duty
(Display Duty)
(unitS)
unitS
(Display Base Units )
(b.rEF)
b.rEF
(Display Bottom Ref )
(ProF)
Display Duty
(Start duty edit)
(duty)
ProF
(Display N-L Profile )
(SCALE/Duty’@max)
SCALE
(Display Scale Factor)
(4)
4
(Display 4mA value)
(20)
20
(Display 20m A value )
(d)
d
(Display Damping )
(AL)
Start duty edit
(Scroll thru duties )
(Confirm duty )
Confirm Duty
(Not save; duty )
(Save; unitS)
Display Base Units
(Start units edit )
(unitS)
Start units edit
(Scroll thru units )
(Confirm units )
Confirm Units
(Not save; unitS )
(Save; b.rEF)
Display Bottom Ref
(Start Bottom
Reference edit )
(b.rEF)
Start B ottom Ref ed it
(Edit flashing digit)
(Confirm edit/B.Ref)
Confirm Bottom Ref
(Not save; b.rEF)
(Save; ProF/SCALE )
Display N -L Profile
(Start profile edit)
(ProF)
Start profile edit
(Scroll thru profiles)
(Confirm profile)
Confirm Profile
(Not save; ProF)
(Save; SCALE)
Display 4mA value
(Start 4mA edit)
(4)
Display 4mA value
(Not save; 4)
(Save it ; 20)
Display 20mA value
(Start 20mA edit)
(20 )
Display 20mA value
(Not save; 20)
(Save it ; d)
Display Damping
(Start damping edit)
(d)
Display Damping
(Not save; d)
(Save; AL)
1
1
r1.On
(Display RL1 On Pt)
(r1. Off)
Display RL 1 On Pt
(Start edit)
(r1.On)
r1.OFF
(Display RL1 Off Pt)
(r2. On)
Display RL 1 Off Pt
(Start edit)
(r1.OFF)
Confirm RL1 Off Pt
(Not save; r1.OFF)
(Save ; r2.On )
r2.On
(Display RL2 On Pt)
(r2. Off)
Display RL 2 On Pt
(Start edit)
(r2.On)
Display RL 2 On Pt
(Not save; r2.On)
(Save it ; r2.OFF)
r2.OFF
(Display RL2 Off Pt)
(SEt 4)
Display RL 2 Off Pt
(Start edit)
(r2.OFF)
Display RL 2 Off Pt
(Not save; r2.OFF)
(Save; SEt 4)
SEt 4
(Display PV @ 4 mA)
(SEt 20 )
Display PV @ 4mA
(Ranging)
(SEt 4)
Ranging
(Flash “4” and PV )
Display PV @ 4mA
(Not save; SEt 4)
(Save; SEt 20)
SEt 20
(Display PV @ 20 mA)
(PV Display)
Display PV @ 20mA
(Ranging)
(SEt 20)
Ranging
(Flash “20” and PV)
Display PV @ 20mA
(Not save; SEt 20 )
(Save; PV Display)
(See Diagnostics menu )
AL
(Display Alarm
Current Action )
(AL )
Display Alarm
Current Action
(Start selection)
(AL)
Start Selection
(Scroll thru options)
(Confirm selection)
Confirm selection
(Not save ; AL)
(Save;
r1.OFF or SEt 4)
Level
@max
(Display max level)
(‘Duty’ @ max)
Display max level
(Start max level edit)
(Level @m ax)
Start max level edit
(Edit flashing digit)
(Confirm digit edit /
max level)
Confirm max level
(Not save;
Level @max)
(Save; ‘Duty@max)
Display Scale Factor
(Start S -Factor edit )
(SCALE)
Start Scale Factor edit
(Edit flashing digit)
(Confirm digit edit /
Scale Factor)
Confirm Scale Factor
(Not Save; SCALE)
(Save; 4)
Content / Flow
Start 4mA edit
(Edit flashing digit)
(Confirm digit edit /
4mA value)
Start 20mA edit
(Edit flashing digit)
(Confirm digit edit /
20mA value)
Start damping edit
(Edit flashing digit)
(Confirm digit edit /
damping value)
Start RL1 On Pt edit
(Edit flashing digit)
(Confirm digit edit /
RL1 On Pt)
Confirm RL1 On Pt
(Not save; r1.On)
(Save; r1.Off)
Start RL1 Off Pt edit
(Edit flashing digit)
(Confirm digit edit /
RL1 Off Pt)
Model 3102
Model 3102Model 3102Model 3102
Start RL2 On Pt edit
(Edit flashing digit)
(Confirm digit edit /
RL2 On Pt)
Start RL2 Off Pt edit
(Edit flashing digit)
(Confirm digit edit /
RL2 Off Pt)
(4mA Ranging)(20mA Ranging)
Content / Flow Leve l / Dista nce
Flow
@max
(Display max level)
(4)
Display max flow
(Start max flow edit)
(Flow @max)
Start max flow edit
(Edit flashing digit)
(Confirm digit edit /
max flow)
Confirm max flow
(Not save;
Flow @max)
(Save; 4)
Flow
Cont
@max
(Display max content)
(4)
Display max content
(Start max cont edit)
(C ont @ max)
Start max cont edit
(Edit flashing digit)
(Confirm digit edit /
max contents)
Confirm max cont
(Not save;
Cont @max)
(Save; 4)