Reference Manual
00809-0100-4840, Rev. BA
July 2008
B-3
Rosemount 3100 Series
HAZARDOUS
LOCATIONS
CERTIFICATIONS
Transmitters that have the following labels attached have been certified to
comply with the requirements of the approval agencies noted.
Factory Mutual (FM)
Approvals
The 3105 only:
Project ID: 3024095
I5 Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D.
Intrinsically Safe for Class I, Zone 0, AEx ia IIC.
Temperature code T4 at +60°C max ambient.
Temperature code T6 at +55°C max ambient.
Control Drawing: 71097/1216
Ui = 30 V, li = 120 mA, Pi = 0.82 W, Li = 108 μH, Ci = 0 μF
Non-incendive for Class I, Division 2, Groups A, B, C and D.
Non-incendive for Class I, Zone 2, AEx nA IIC
Temperature code T4 at +60°C max ambient.
Temperature code T6 at +55°C max ambient.
Control Drawing: 71097/1216
Ui = 30 V, li = 120 mA, Pi = 0.82 W, Li = 108 μH, Ci = 0 μF
Figure B-1. Approval Labels
Factory Mutual (FM)
WARNING
RISK OF ELECTROSTATIC CHARGE BUILD UP ON PLASTIC
SURFACES. CLEAN ONLY WITH A DAMP CLOTH
LEVEL TRANSMITTER
3100 SERIES ULTRASONIC
3105xxxxxx
moc.tnuomesor.www
xxxx
3105xxxxxxI5xx
SUBSTITUTION OF COMPONENTS MAY
IMPAIR SAFETY OF THIS EQUIPMENT
REFER TO CONTROL
DRAWING NO. 71097/1216
FM
APPROVED
Ui:30V Ii:120mA Pi:0.82W Ci:0µF Li:108µH
T4(-40°C ≤ Ta ≤ +60°C) T6(-40°C ≤ Ta ≤ +55°C)
AEx Ia IIC
AEx nA IIC
CL Div 1 Gps. A,B,C,D
CL Div 2 Gps. A,B,C,D
I
I
TYPE 4X / IP66
12...30 Vdc 4-20mA
-30...+70°C -0.25...+3 bar
Made in:
Model No.
K9831_3105_FM_IS K9827_3105_NAMEPLATE