WEIGHING1 LOG
03.07.06 02:11:27
TARE : NO
LOG CLEAR : NO
ACT AVERAGE : 151GR
YSTR AVERAGE: 143GR
TOTAL WEIGH : 980GR
DAY NUMBER : 12
DATE: The unit shows current date (day.month.year).
TIME: The unit shows current time (hour.minute.second).
LOG CLEAR: Clear today and yesterday log fields (Range: NO- YES / Factory Setting: NO).
ACT AVERAGE: Actual average weigh (GR).
Number Of Record: Quantitiy of recorded weigh in WEIGHING PARAMETERS PAGE AW SMPL PER time.
Number Of Record can’t be lower than WEIGHING PARAMETERS PAGE AW MIN SMP.
If Number Of Record is lower than WEIGHING PARAMETERS PAGE AW MIN SMP,
new ACTUAL AVERAGE WEIGH is not calculated and EPC keeps on using old ACTUAL AVERAGE WEIGH
till Number Of Record will reach to WEIGHING PARAMETERS PAGE AW MIN SMP.
YSTR AVERAGE: Yesterday average weigh(GR).
Number Of Yesterday’s Records: Quantitiy of recorded weigh in yesterday.
5.4.4 WEIGHING LOG (EPC 4)
3
Record No=1
Record No=Number Of Record
WEIGHT[Record No]
Number Of Record
ACTUAL AVERAGE WEIGH =
3
Record No=1
Record No=Number Of Yesterday’s Records
WEIGHT[Record No]
Number Of Record
YESTERDAY AVERAGE WEIGH =
WEIGHING3 LOG
03.07.06 02:11:27
TARE : NO
LOG CLEAR : NO
ACT AVERAGE : 351GR
YSTR AVERAGE: 348GR
TOTAL WEIGH : 3980GR
DAY NUMBER : 12
WEIGHING2 LOG
03.07.06 02:11:27
TARE : NO
LOG CLEAR : NO
ACT AVERAGE : 467GR
YSTR AVERAGE: 458GR
TOTAL WEIGH : 1400GR
DAY NUMBER : 12
24
(NOTE-1)
NOTE-1: If the device is EPC-4A then this page is not shown.