SET VALUES
TEMP.HOUSE: 20.0°C
TEMP.HEAT : -2.0°C
TEMP.COOL : 2.0°C
HUMIDITY : 20%
VENT.MIN : 0%00
VENT.MAX : 8%00
DAY : -5
TEMP.HOUSE: Temperature house set value (Range: 0.0 °C - 50.0 °C / Factory Setting: 30.0 °C).
TEMP. HEAT: Temperature heat set value
(If HEATING1 PARAMETERS PAGE SET POINT or HEATING2 PARAMETERS PAGE SET POINT is
ABSOLUTE then; Range: 0.0 °C - 40.0 °C otherwise, Range: -9.9 °C - 0.0 °C / Factory Setting: -0.5 °C)
HEATING1 PARAMETERS PAGE SET POINT and HEATING2 PARAMETERS PAGE SET POINT
parameters are the same.
TEMP.COOL: Temperature cool set value
(If COOLING PARAMETERS PAGE SET POINT is ABSOLUTE then
Range: 0.0 °C - 40.0 °C otherwise 0.0 °C - 9.9 °C/ Factory Setting: 4.0 °C)
HUMIDITY: Humidity set value (Range: 0% RH - 100% RH / Factory Setting: 65% RH).
VENT.MIN: Minimum ventilation set value (Range: 0%00 - 8%00 / Factory Setting: 0%00).
VENT.MAX: Maximum ventilation set value (Range: 0%00 - 8%00 / Factory Setting: 8%00)
DAY: Current day set number. PROCESS VALUES PAGE DAY, SET VALUES PAGE DAY are the same
parameters.
SET VALUES PAGE DAY parameter can change. (Range: -5 - 999 / Factory Setting: -1)
5.4.7 SET VALUES
SET VALUES
TEMP.HEAT : -2.0°C
TEMP.COOL : 2.0°C
DAY : -5
CURVE is DISABLED
CURVE is ENABLED
Page I Page II
SET SHUTTER
CORRMINVENT: 0%
CORRMAXVENT: 0%
CORRPBVENT : 0.0%
CORRMINVENT: Shutter minimum set value depends on Min. Vent. set value
(Range: -20% - 20% / Factory Setting: 0%)
CORRMAXVENT: Shutter maximum set value depends on Max. Vent. set value
(Range: -20% - 20% / Factory Setting: 0%)
CORRPBVENT: Correction for Shutter set value depends on ventilation
(Range: -9% - 70 % / Factory Setting: 0.0 %)
Push button to access to ALARM SET VALUES PAGE (If no parameter is selected)
Push button to access to PROCESS VALUES PAGE (If no parameter is selected)
Push button to access to FEEDING PARAMETERS PAGE (If the last parameter is selected)
5.4.8.1 SHUTTER PARAMETERS
5.4.8 SHUTTER
SET VALUES page showing depends on curve selection.
If curve is enabled “Page II” is seen, otherwise “Page I” is seen.