Micropilot FMR20 HART Technical data
Endress+Hauser 67
Process pressure range, UNI flange process connection
• p
gauge
= –1 to 1 bar (–14.5 to 14.5 psi)
• p
abs
< 2 bar (29 psi)
The pressure range may be further restricted in the event of a CRN approval.
Dielectric constant For solids
• ε
r
≥ 2
• Contact Endress+Hauser for lower ε
r
values
For dielectric constants (DC values) of many media commonly used in various
industries refer to:
• the Endress+Hauser DC manual (CP01076F)
• the Endress+Hauser "DC Values App" (available for Android and iOS)