Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus The "Expert" menu
Endress+Hauser 105
Navigation Expert → Sensor → Mapping → Distance
Write access Read-only parameter
Description Displays the currently measured distance.
Mapping end point (1022)
Navigation Expert → Sensor → Mapping → Mapping end point
Write access Maintenance
Prerequisite Only visible if the Manual map option has been selected in the Confirm distance
parameter.
Description Definition of the distance up to which the mapping curve will be recorded.
Input range 0.1 m (0.33 ft) to Tank/silo height
Factory setting 0.1 m (0.33 ft)
Additional information The distance is measured from the reference point, i.e. from the lower edge of the
mounting flange or the threaded connection.
On the local display the Present mapping parameter is displayed together with this
parameter. Present mapping states up to which distance a mapping has already been
recorded.
Present mapping (1182)
Navigation Expert → Sensor → Mapping → Present mapping
Write access Read-only parameter
Description Indicates up to which distance a mapping has already been recorded.
Record map (1069)
Navigation Expert → Sensor → Mapping → Record map
Write access Maintenance
Prerequisite Only visible if a value has been entered into the Mapping end point parameter.
Description Starts the recording of the map.