 16 "In safety distance" = "Warning": If the safety distance is undershot, the device continues measuring but
nevertheless generates a warning.
1 Safety distance
0
L
E
S942
1
t
2
3
A0016213
 17 "In safety distance" = "Self holding": If the safety distance is undershot, the device generates an alarm. The
measurement is not resumed until this alarm has been acknowledged by the user.
1 Safety distance
2 Defined alarm output value
3 Acknowledge alarm
Parameter Meaning Parameter description
Safety distance Length of the safety distance as measured from the reference
point of the measurement.
(→  93)
In safety distance Defines the behavior in case the safety distance is undershot. (→  93)
Acknowledge alarm Reactivates the measurement after the level has fallen below
the safety distance again
1)
.
(→  94)
1) Only required for "In safety distance" = "Self holding"