Device Functions Proline Promag 55 FOUNDATION Fieldbus 3 Block MEASURED VARIABLES
Endress+Hauser 13
3.2.2 Function group ADDITIONAL CONFIGURATION
MEASURED
VARIABLES
A MEASURING VALUES AAA
SYSTEM UNITS ACA CONFIGURATION 040
ADDITIONAL CONF. 042
Function description
MEASURED VARIABLES SYSTEM UNITS ADDITIONAL CONFIGURATION
UNIT DENSITY
(0420)
Use this function to select the unit for displaying the fluid density.
The unit you select here is also valid for:
Fluid density entry
Options:
Metric g/cm
3
; g/cc; kg/dm
3
; kg/l; kg/m
3
; SD 4 °C, SD 15 °C, SD 20 °C; SG 4 °C,
SG 15 °C, SG 20 °C; g/l
US lb/ft
3
; lb/gal; lb/bbl (normal fluids); lb/bbl (beer); lb/bbl (petrochemicals);
lb/bbl (filling tanks)
Imperial lb/gal; lb/bbl (beer); lb/bbl (petrochemicals)
Factory setting:
kg/l (SI units: not for USA and Canada)
g/cc (US units: only for USA and Canada)
SD = Specific Density, SG = Specific Gravity
The specific density is the ratio of fluid density to water density
(at water temperature = 4, 15, 20 °C).
UNIT LENGTH
(0424)
Use this function to select the unit for displaying the length of the nominal diameter.
The unit you select here is also valid for:
Nominal diameter of sensor (function NOMINAL DIAMETER (6804) on Page 51)
Options:
MILLIMETER
INCH
Factory setting:
MILLIMETER (SI units: not for USA and Canada)
INCH (US units: only for USA and Canada)