Promass 40 10 Technical data
Endress+Hauser 57
10.1.10 Mechanical construction
Design / dimensions see Page 59 ff.
Weight
Materials Transmitter housing:
Compact housing: powder coated die-cast aluminium
Sensor housing:
Acid- and alkali-resistant outer surface;
Stainless steel 1.4301/304
Process connections:
Flanges DIN / ANSI / JIS stainless steel 1.4404/316L
Flange DIN 11864-2 stainless steel 1.4404/316L
VCO connection stainless steel 1.4404 (316L)
Hygienic coupling DIN 11851 / SMS 1145 stainless steel 1.4404 (316L)
Threaded unions ISO 2853 / DIN 11864-1 stainless steel 1.4404/316L
Tri-Clamp stainless steel 1.4404 (316L)
Measuring tubes:
Stainless steel 1.4539/904L
Seals:
Welded process connections without internal seals
Material load diagram The material load curves (pressure-temperature diagrams) for the process connections
are to be found in the following documents:
Technical Information Promass 40 E (TI 055D/06/en)
Process connections
VCO coupling, flanges (DIN 2501, ANSI B16.5, JIS B2238)
Sanitary connections: Tri-Clamp, threaded unions (DIN 11851, SMS 1145, ISO 2853,
DIN 11864-1), flange to DIN 11864-2
10.1.11 Human interface
Display element Liquid crystal display (option): illuminated, two lines with 16 characters per line
Selectable display of different measured values and status variables
Remote operation Operation by means of:
HART protocol (handheld communicator)
FieldTool™” configuration and service program from Endress+Hauser
Promass E / DN 8 15 25 40 50
Weight in [kg] 8 8 10 15 22