EasyManua.ls Logo

Endress+Hauser Promass 40 - SMS 1145 Connections (Hygienic Coupling)

Endress+Hauser Promass 40
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Technical data Promass 40
68 Endress+Hauser
Dimensions Promass E: SMS 1145 connections (hygienic coupling)
Fig. 30: Dimensions Promass E: SMS 1145 connections (hygienic coupling)
Hygienic coupling SMS 1145: 1.4404/316L
DN A B C G L U di
8 317 224 93 Rd 40 x 1/6" 229 22.5 5.35
15 331 226 105 Rd 40 x 1/6" 273 22.5 8.30
25 337 231 106 Rd 40 x 1/6" 324 22.5 12.00
40 358 237 121 Rd 60 x 1/6" 456 35.5 17.60
50 423 253 170 Rd 70 x 1/6" 562 48.5 26.00
3-A version also available (Ra
0.8 µm/150 grit)
F06-40Exxxxx-06-00-xx-xx-002