Solicap M FTI55, FTI56 Installation
Endress+Hauser 19
3.7 Rod probes FTI55
!
Note!
Total length of the probe from the start of the thread: L = L1 + L3
(+ 125 mm with active buildup compensation)
Rod probe
partially insulated
Rod probe
fully insulated
Rod probe
with inactive length
partially/fully insulated
Rod probe with active
buildup compensation
partially insulated
TI418Fen39
H2 77 77 66 92
H3 25 25 25 25
Across flats (AF) 50 50 50 50
Total length (L) 200...4000 200...4000 300...6000 225...4000
Active rod length (L1) 200...4000 200...4000 200...4000 200...4000
Inactive rod length (L3) - - 200...2000 -
ø Inactive length - - 43 -
Length of partial insulation (L2) 75 - 75 / - 75
Probe rod diameter (with insulation) 18
(25)
18
(25)
18
(25)
18
(25)
ø Active build-up compensation/
length
- / - - / - - / -
36/
125
Lateral loading capacity (Nm) at 20 °C 300 300 300 200
Maximum process temperature (°C) 180 80 180/80 180
For use in mounting nozzles - - X -
In the event of condensate on tank
ceiling
--XX
X = recommended
L1/L2/L3
NPT / R
H2
L1
L2
L1
L1
L3
L2
L1
125
L2
H2
H3
H2
H3
H2
H2H2
H3
H2H2
H3
AF AF AF AF
Length tolerance Up to 1 m: 0 to –5 mm > 1 m to 3 m: 0 to –10 mm > 3 m to 6 m: 0 to –20 mm