EN Troubleshooting
System switched off due to water shortage
Reason Solution
Insufficient water in the vaporiser
and the 3-minute refill period has
expired.
Refill water.
Install automatic filling (FWA), if
necessary.
Malfunction when automatically
filling water.
Check water supply. Clean the fil-
ter at the water supply connector
if necessary.
No water supply, water inlet valve
clogged, blocked, or defective.
Clean the water inlet valve and
check that it functions properly.
Replace the water inlet valve if
necessary.
This error message must be confirmed once the error is rectified:
- Briefly press the On/Off button once.
- Press the On/Off button for 3 seconds to restart.
Safety circuit for safety temperature limiter interrupted
Reason Solution
Safety temperature limiter is trig-
gered.
Rectify the reason for overheating.
Replace the safety temperature
limiter.
Error during bus configuration
Reason Solution
The same module address is
assigned to multiple bus modules
on the control unit.
Check the module address.
Hardware error
Reason Solution
E.g. over/under voltage Contact EOS Service. See Service
address, EN-92