EPSON Stylus Photo 925 Revision A
Disassembly and Assembly Disassembly 111
12. Remove the Paper Eject Roller from the hooks on the Paper Guide Front.
Figure 4-80. Removing the Paper Eject Roller
Hooks
T When installing the Front Frame, tighten the screws in the
numerical order as shown below.
Figure 4-81. Installing the Front Frame
T Install the PF Scale by referring to 4.2.18.1 “PF Scale
installation”.
T Tightening torque for screws
Three screws securing the Front Frame:
C.B.S. SCREW, 3x6, F/ZN
: 8 ~ 10kgf.cm
A D J U S T M E N T
R E Q U I R E D
T Once the Paper Eject Roller has been removed or when it has
been replaced with a new one, be sure to apply an appropriate
amount of grease G-26 to the bore of the bush. (Refer to Figure
6-13. “Lubrication point 12” in Chapter 6.)
T Once the combination gear 13.6, 33 has been removed or when it
has been replaced with a new one, be sure to apply an
appropriate amount of grease G-26 to the specified points. (Refer
to Figure 6-10. “Lubrication point 9” in Chapter 6.)
T Once the Front Frame has been removed or when it has been
replaced with a new one, be sure to apply an appropriate amount
of grease G-26 to the specified points. (Refer to Figure 6-8.
“Lubrication point 7” in Chapter 6.)