EPSON Stylus Photo 925 Revision A
Disassembly and Assembly Disassembly 79
4.2.1 Housing removal
1. Open the printer cover and remove the two screws (C.B.S TITE-R SCREW, 3x6,
F/UC) securing the Housing in the front of the printer body.
Figure 4-2. Removing the two screws in the Front of the Housing
2. Remove the three screws (C.B.S SCREW, 3x6, F/ZN) securing the Housing at the
rear of the printer.
Figure 4-3. Removing the two screws at the Rear of the Housing
3. Lift the rear of the Housing slightly, disconnect the Panel FFC from the Main
Board and remove the Housing.
Figure 4-4. Removing the Housing
C A U T I O N
T Ensure that C.B.S-TITE-R 3 x 6 F/US screws are used for the
two screws on the front side of the printer. The tips of these
screws are rounded for user’s safety.
C.B.S TITE-R SCREW, 3x6, F/UC
C.B.S SCREW, 3x6, F/ZN
Panel FFC