Installing a MINI-LINK 6351
5.3.1 Connecting the Earthing Cable
Danger!
Grounding of the packet radio is a safety requirement. The other end of the
earthing cable must be connected to mast ground.
Figure 9
1. Connect the earthing cable to the packet radio. Connect the other end of
the earthing cable to mast ground.
5.4 Installing PoE Equipment and Cable
PoE provides the MINI-LINK 6351 with both traffic and power through a single
cable. It is also possible to protect the MINI-LINK 6351 from overvoltage by
using an Ethernet surge protector.
The PoE injector can be mounted either indoor or outdoor, as shown in Figure
10. This installation procedure is valid for both cases.
26
13/1531-HRA 901 17/9 Uen B | 2016-03-04