Installing a MINI-LINK 6351
Max 1.0 m
(40")
Max 1.0 m
(40")
A
15529
Figure 12 Recommended Distances Between Clamps and Minimum Bending
Radius (A)
Never over-bend the cable. Figure 13 shows the minimum bending radius
for the PoE cable.
Cable
64 mm
64 mm
64 mm
64 mm
64 mm
64 mm
Acceptable Not acceptable
(too sharp bend)
Figure 13 Minimum Bending Radius
The same type of cable clamp is used for both single and multiple MINI-LINK
6351 installations. A maximum number of three clamps can be stacked upon
each other for fitting either horizontally or vertically. Secure the clamps to each
other by nut and bolt and to the mast with straps. For multiple stacking, there is
one stacking kit for two clamps and one for three clamps available for ordering.
Each clamp has three strap holes A , B, and C as shown in Figure 14. Strap
hole A is used when the clamp is fitted horizontally to the mast. Strap holes B
and C are used when the clamp is fitted vertically to the mast.