Settings Setting range In steps of Value after
resetting
AC balance
3)
25 - 75% 1 50%
AC offset
3)
-300-+ A/-10 +10V 1 A / 0.1 V 0
Start data
2)
Flux pre-flow 0 - 99.0 s 0.1 s 0 s
Start adjust Min = 50% 1% 100%
Start type Direct orScratch - Direct
Wire creep start Auto orSet speed - Auto
Wire creep start speed 0 - 1000 cm/min 1 cm/min 20 cm/min
Start phases OFF orON - OFF
Open-circuit voltage OFF orON - OFF
Maximum open-circuit voltage 5 - 60 V 0.1 V 50 V
Stop data
2)
Flux post-flow 0 - 99.0 s 0.1 s 0 s
Crater filling OFF orON - OFF
Crater filling time 0 - 10 s 0.01 s 0.0 s
Burnback time 0- 10 s 0.01 s 0.65 s
Stop phases OFF orON - OFF
Control parameters
Dynamics Auto orSet values - Auto
Inductance Auto orSet values - Auto
Setting limits - - -