10 TOOLS
0460 949 474
- 68 -
© ESAB AB 2021
PRODUCTION STATISTICS
LAST WELD TOTAL
ARCTIME
CONSUMED WIRE
BASED ON
NUMBER OF WELDS
CONSUMED ICE WIRE
DEPOSITION RATE
0s
0g
1g/m
0 kg/h
0s
0g
0
0 kg/h
LAST RESET 081114 08:38:03
RESET UPDATE QUIT
When you press RESET, all counters are reset. Date and time show the most recent reset.
If you do not reset the counters, these are all automatically reset when one of them has
reached its maximum value.
Maximum counter values
Time 999 hours, 59 minutes, 59 seconds
Weight 13350000 grams
Quantity 65535
10.7 Quality functions
MAIN MENU » TOOLS » QUALITY FUNCTIONS
Quality functions keep track of various interesting weld data for individual welds.
These functions are:
• Time of welding start.
• Duration of welding.
• Maximum, minimum and average current during welding.
• Maximum, minimum and average voltage during welding.
• Maximum, minimum and average energy per unit length during welding.
The number of welds since the most recent reset is displayed in the row at the bottom.
Information can be stored about a maximum of 100 welds. In the event of more than 100
welds, the first one is overwritten.
The most recently noted weld is presented in the display, although it is also possible to
browse between other noted welds. All logs are deleted when you press RESET.
QUALITY FUNCTIONS
#WELD: 1 / 4
START 20190807 15:59:14
WELD TIME 00:00:20 WELD DATA:
HEAT INPUT: 3.12 kJ/min