EasyManua.ls Logo

ESAB A2 PEK - Active Errors; Unit Ids; Description of Fault Management Codes

ESAB A2 PEK
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 TOOLS
0460 949 474
- 60 -
© ESAB AB 2021
The unit in which the error has occurred, see section "Unit IDs"
The error's error management code, see section "Description of fault management
codes"
ERROR LOG
Index Date Time Unit Error
1 081120 11:24:13 8 19
2 081120 10:24:18 8 18
3 081121 13:24:18 8 17
Error in battery-driven memory
DELETE ALL QUIT
10.1.2 Active errors
MAIN MENU » TOOLS » EVENT HANDLING » ACTIVE ERRORS
The Active errors menu shows only the errors active for the moment.
ACTIVE ERRORS
Error nr Node ID Device type
78 1 powersource
152 1 powersource
Error nr 78
QUIT
10.1.3 Unit IDs
Explanation of unit IDs for LAF and TAF power source:
2= Power source
6= Wire feed and travel motion (motor board)
8= Control panel
NOTE!
The unit IDs specified above apply to LAF and TAF power sources, and constitutes an
example of unit IDs for Aristo®1000, as the nodes in an Aristo®1000 application
may have different ID numbers depending on the configuration of the equipment.
10.1.4 Description of fault management codes
The fault management codes that users can correct themselves are given below. If another
code appears, restart the machine and if the error persists, contact a service technician.
6 High temperature
The power source has overheated. Welding is cancelled. Welding is permitted again when the
temperature falls below the maximum temperature parameter.
1. Check that the cooling air inlets or outlets are not obstructed or clogged with dirt.
2. Check the duty cycle being used, to make sure that the equipment is not being overloaded.

Table of Contents