4 GAS METAL ARC WELDING
0460 949 474
- 20 -
© ESAB AB 2021
Settings Setting range In steps of Value after
resetting
Crater filling time 0 - 10 s 0.01 s 0.0 s
Burnback time 0- 10 s 0.01 s 0.20 s
Stop phases OFF orON - OFF
Dynamic regulation Auto orSet values - Auto
Setting limits - - -
Measure limits - - -
*) The setting range is dependent on the product used.